RTT15-T1LW4TBC-C2 | Foxboro RTT15 I/A Series Temperature Transmitter
Артикул: QT-40202
от 716 068 ₸
В наличии: 0
Предложения складов
Склад
Цена
В тенге
Остаток
Доставка
Характеристики
Estimated Lead Time
6 - 8 Weeks
ID каталога
44020
Manufacturer
FoxboroOrdering InformationModel: RTT15 - I/A Series® Temperature TransmitterOutput Version: -T - Intelligent; Digital HART 5 and 4 to 20 mA dcInput Configuration(1): 1 - Single Input; Configured for One SensorHousing and Sensor Mounting (Integral Sensor and Well): L - Universal Housing. aluminum; with Integral Sensor and WellSensor Length - Dimension U or U + T(2): W - 7.5 in (191 mm), Sensor includedMeasurement Input Type (Software Selectable)(3): 4 - RTD, Platinum, 4-wire, 100 O, IEC 751 (AST
Model
RTT15 I/A Series Temperature Transmitter
Part Number
RTT15-T1LW4TBC-C2
Shipping Weight
3 Kg
Артикул
RTT15-T1LW4TBC-C2
Описание
Part Number: RTT15-T1LW4TBC-C2Model: RTT15 I/A Series Temperature TransmitterManufacturer: FoxboroOrdering InformationModel: RTT15 - I/A Series® Temperature TransmitterOutput Version: -T - Intelligent; Digital HART 5 and 4 to 20 mA dcInput Configuration(1): 1 - Single Input; Configured for One SensorHousing and Sensor Mounting (Integral Sensor and Well): L - Universal Housing. aluminum; with Integral Sensor and WellSensor Length - Dimension U or U + T(2): W - 7.5 in (191 mm), Sensor includedMeasurement Input Type (Software Selectable)(3): 4 - RTD, Platinum, 4-wire, 100 O, IEC 751 (ASTM-B Standard Accuracy), 316 ss SheathThermowell Assembled to Housing: TB Well TypeWell ConnectionWell MaterialAvailable with Sensor Length CodesPlain3/4 NPT External316 ssA, D, G, J, L, P, and RElectrical Safety: C - CSA, Intrinsically Safe, Explosionproof, and Division 2(4),(5),(6)Optional Selections - Miscellaneous: -C2 - Custom Database Configuration (Requires C2 Form filled out with all data specified)Input configuration can be changed in the field by changing wiring terminations and reconfiguring.Quantity of one Foxboro sensor that is listed under Measurement Input Type. Length is Dimension U or U + T as shown in the Dimensions-Nominal section of PSS 2A-1F5 A and in DP 020-462, where U is the insertion length, and T is the lagging length of 76 mm (3 in). See Note (d) below.Transmitter is configured for measurement type specified, whether sensor is included or not. User can change configuration to a different type using the appropriate configurator for selected protocol.Flameproof and explosionproof approvals and certifications not available with Thermowell Code NA (user-supplied thermowell).For HART version 7 (-H), contact Global Customer Support for availability of CSA and FM certification.With Option -L1, CSA is explosionproof only.