Назад в каталог
Промышленное оборудование · Yokogawa FLXA202 2-Wire Analyzer

FLXA202-D-C-D-AB-P1-NN-A-N-LA-N-NN/U/SCT/CD4 | Yokogawa FLXA202 2-Wire Analyzer

Артикул: QT-2338
от 1 440 661 ₸
В наличии: 0


Предложения складов

СкладЦенаВ тенгеОстатокДоставка

Характеристики

Estimated Lead Time10 - 12 Weeks
ID каталога2408
ModelFLXA202 - 2-Wire AnalyzerPower Supply: -D - Always -DHousing (Note 1): -C - Aluminum alloy cast + epoxy coatingDisplay (Note 2): -D - Anti-glare LCDType (Note 3): -AB - General purpose for CE, RCM1st Input: -P1 - pH/ORP (Note 4)2nd Input (Note 5): -NN - Without inputOutput: -A - 4-20 mA + HART-N: Always NLanguage Set (Note 6): -LA - English and 11 languagesCountry (Note 7): -N - Global except Japan-NN: Always -NNMounting Hardware: /U - Pipe and wall mounting hardwareTag plate: /SCT - Stainless s
Part NumberFLXA202-D-C-D-AB-P1-NN-A-N-LA-N-NN/U/SCT/CD4Ordering Information
Shipping Weight7 Kg
АртикулFLXA202-D-C-D-AB-P1-NN-A-N-LA-N-NN/U/SCT/CD4

Описание

Part Number: FLXA202-D-C-D-AB-P1-NN-A-N-LA-N-NN/U/SCT/CD4Ordering InformationModel: FLXA202 - 2-Wire AnalyzerPower Supply: -D - Always -DHousing (Note 1): -C - Aluminum alloy cast + epoxy coatingDisplay (Note 2): -D - Anti-glare LCDType (Note 3): -AB - General purpose for CE, RCM1st Input: -P1 - pH/ORP (Note 4)2nd Input (Note 5): -NN - Without inputOutput: -A - 4-20 mA + HART-N: Always NLanguage Set (Note 6): -LA - English and 11 languagesCountry (Note 7): -N - Global except Japan-NN: Always -NNMounting Hardware: /U - Pipe and wall mounting hardwareTag plate: /SCT - Stainless steel tag plateConduit adapter (Note 8): /CD4 - Conduit adapterNOTE:Urethane coating is for acid resistance, and epoxy coating is for alkali resistance. For high anti-corrosion coating, both urethane coating and epoxy coating are applied.Type -CF is anti-reflection coated. Other types are anti-glare coated.Type -C * is intrinsic safety (IS), Type -DB is type n of ATEX and IECEx, Type -DD is nonincendive (NI) of FM and CSAType -DE is type n of CSA.This input is to be come from an analog pH/ORP sensor.When a 2nd input is selected, only the same kind of the 1st input is available.For example, when a 1st input is -P1 , the 2nd input must be the same -P1.The combination of ISC and ISC is not available. And, the combination of SENCOM sensor and SENCOM sensor is not available, either.These languages are message languages on the analyzer s display.One analyzer has English and 11 languages.All languages are as follows; English, Chinese, Czech, French, German, Italian, Japanese, Korean, Polish, Portuguese, Russian and Spanish.When an analyzer is used in Japan, it must meet the Japanese Measurement Law, please select the -J.Only SI units must be used on the analyzer and its documents in Japan./CB5 , /CD5 , /CF5 can use type n model (-DB, -DE), other model can use /CB4 , /CD4 , /CF4 .

Документы