Промышленное оборудование · Yokogawa EJA530E In-Line Mount Gauge
EJA530E-FDS7N-02CDL/KF22/D3/M15/T08/HE | Yokogawa EJA530E In-Line Mount Gauge Pressure Transmitter
Артикул: QT-91846
от 838 254 ₸
В наличии: 0
Предложения складов
Склад
Цена
В тенге
Остаток
Доставка
Характеристики
Condition
New & Original in Factory Packing
Estimated Lead Time
12 - 20 Weeks
Factory Warranty
12 Months
ID каталога
99854
Model
EJA530E In-Line Mount Gauge Pressure TransmitterBrand: Yokogawa
Part Number
EJA530E-FDS7N-02CDL/KF22/D3/M15/T08/HE
Shipping Weight
6 Kg
Артикул
EJA530E-FDS7N-02CDL/KF22/D3/M15/T08/HE
Описание
OverviewThe EJA-E series of transmitters is Yokogawa's most recent evolution of the DPharp family. Released in 2012, it combines the ruggedness and success of the work-horse EJA-E series with the performance of the thoroughbred EJX-A series to deliver the type of product you have come to expect from Yokogawa.EJA530E's standard features include:±0.055% Accuracy (0.04% Accuracy optional)±0.1% Stability per 10 years90 ms Response TimeExida and TUV SIL2/SIL3 CertifiedLocal Parameter Setting (LPS)SpecificationsMeasurement TypesPrimary Variable: Gauge PressureReference AccuracyPrimary Variable: ±0.055% of Span±0.04% of Span (/HAC option)Stability (All Normal Operating Conditions)Primary Variable: ±0.1% of URL per 10 yearsResponse TimePrimary Variable: 90 msecRangeability:Primary Variable:A, B and C Capsules: 20:1D Capsules: 10:1Model and Suffix Codes Model EJA530E Gauge pressure transmitter Output signal -F Digital communication (FOUNDATION Fieldbus protocol, refer to GS 01C31T02-01EN) Measurement span (capsule) D 5 to 50 MPa (720 to 7200 psi)(1) Wetted parts material(2) S Process connector: 316L SST)#Diaphragm: Hastelloy C-276(3)#Others: 316L SST)# Process connection 7 1/2 NPT male N Always N -0 Always 0 Amplifier housing 2 ASTM CF-8M stainless steel(4) Electrical connection C 1/2 NPT female, two electrical connections and a 316 SST blind plug Integral indicator D Digital indicator(5) Mounting bracket L 316 SST 2-inch pipe mounting ATEX /KF22 ATEX Flameproof Approval(5)Applicable Standard: EN 60079-0:2012/A11:2013, EN 60079-1:2007, EN 60079-31:2014Certificate: KEMA 07ATEX0109 XII 2G, 2D Ex d IIC T6...T4 Gb, Ex tb IIIC T85°C DbDegree of protection: IP66/IP67Amb. Temp. (Tamb) for gas-proof :T4; –50 to 75°C (–58 to 167°F), T5; –50 to 80°C (–58 to 176°F), T6; –50 to 75°C (–58 to 167°F)Process Temp. for gas-proof (Tp):T4; –50 to 120°C (–58 to 248°F), T5; –50 to 100°C (–58 to 212°F), T6; –50 to 85°C (–58 to 185°F)Max. surface Temp. for dust-proof: T85°C (Tamb: –30 to 75°C, Tp: –30 to 85°C)(6) Calibration units(7) /D3bar calibration (bar unit) Material certificate(8) /M15 Process Connector Pressure test/ Leak test certificate(9) /T08 Test Pressure: 50 MPa (7200 psi)(10)Nitrogen(N2) Gas or Water(11)Retention time: one minute Fluoro-rubber O-ring /HE All O-rings of amplifier housing. Lower limit of ambient temperature: –15°C (5°F) The “•” marks indicates the most typical selection for each specification.The ‘#’marks indicate the construction materials conform to NACE material recommendations per MR0175/ISO 15156. Please refer to the latest standards for details. Selected materials also conform to NACE MR0103.5 to 70 MPa (720 to 10150 psi) when /HG is specified.Users must consider the characteristics of selected wetted parts material and the influence of process fluids. The use of inappropriate materials can result in the leakage of corrosive process fluids and cause injury to personnel and/or damage to plant facilities. It is also possible that the diaphragm itself can be damaged and that material from the broken diaphragm and the fill fluid can contaminate the user’s process fluids.Hastelloy C-276 or ASTM N10276.Not applicable for electrical connection code 0, 5, 7 or 9.Applicable for Electrical connection code 2, 4, 7, 9, C and D.Lower limit of ambient temperature is –15°C (5°F) when /HE is specified.The unit of MWP (Max. working pressure) on the name plate of a housing is the same unit as specified by option codes D1, D3, and D4.Material traceability certification, per EN 10204 3.1 B.The unit on the certificate is always kPa/MPa regardless of selection of option code D1, D3 and D4.Applicable for capsule code D without /HG.Pure nitrogen gas or pure water is used for oil-prohibited use (option codes K1 and K2).