Назад в каталог
Промышленное оборудование · Yokogawa

EJA110E-JMS4G-72DEK/NS21/M11/D3/T12/C1 | Yokogawa EJA110E Differential Pressure Transmitter

Артикул: QT-92693
от 793 358 ₸
В наличии: 0


Предложения складов

СкладЦенаВ тенгеОстатокДоставка

Характеристики

ConditionNew & Original in Factory Packing
Estimated Lead Time3 - 5 Months
Factory Warranty12 Months
ID каталога100704
ManufacturerYokogawa
ModelEJA110E Differential Pressure Transmitter
Part NumberEJA110E-JMS4G-72DEK/NS21/M11/D3/T12/C1
Shipping Weight8 Kg
АртикулEJA110E-JMS4G-72DEK/NS21/M11/D3/T12/C1
Срок поставки3 - 5 Months

Описание

EJA110E features include:0.055% Accuracy (0.04% Accuracy optional)0.1% Stability per 10 years90 ms Response TimeExida and TUV SIL 2 / SIL3 CertifiedMWP 2,300 psi (MWP 3,600 psi option)Local Parameter Setting (LPS)Ordering Information Model EJA110E Differential pressure transmitter Output signal -J 4 to 20 mA DC with digital communication (HART 5/HART 7 protocol)(1) Measurement span (capsule) M 1 to 100 kPa (4 to 400 inH2O) Wetted parts material(2) S# Cover flange and process connector: ASTM CF-8M(3)Capsule: Hastelloy C-276(4) F316L SST, 316L SST (Others)Capsule gasket: Teflon-coated 316L SSTVent/Drain plug: 316 SST Process connections 4 with 1/2 NPT female process connector Bolts and nuts material G 316L SST Installation -7 Vertical piping, left side high pressure, and process connection downside Amplifier housing 2 ASTM CF-8M stainless steel(5) Electrical connection D M20 female, two electrical connections and a SUS316 blind plug Integral indicator E Digital indicator with the range setting switch (push button)(6) Mounting bracket K 316 SST or SCS14A 2-inch pipe mounting, L type (for vertical piping) /NS21 Material certificate(7)(8) /M11 Cover flange, Process connector(9) Calibration units(10) /D3 bar calibration (bar unit) Pressure test/ Leak test certificate(11)(12) /T12 Test Pressure: 16 MPa(2300 psi)Nitrogen Gas(13)Retention time: one minute Output limits and failure operation(14) /C1 Failure alarm down-scale: Output status at CPU failure and hardware error is -5%, 3.2mA DC or less for 4 to 20 mA output type and -5%, 0.8V DC or less for 1 to 5 V output type. The “*” marks indicate the most typical selection for each specification. HART 5 or HART 7 is selectable. Specify upon ordering.Users must consider the characteristics of selected wetted parts material and the influence of process fluids. The use of inappropriate materials can result in the leakage of corrosive process fluids and cause injury to personnel and/or damage to plant facilities. It is also possible that the diaphragm itself can be damaged and that material from the broken diaphragm and the fill fluid can contaminate the user’s process fluids.Cast version of 316 SST. Equivalent to SCS14A.Hastelloy C-276 or ASTM N10276.Not applicable for electrical connection code 0, 5, 7 and 9.Not applicable for output signal code F.Material traceability certification, per EN 10204 3.1B.Not applicable with process connections code for diaphragm seal system B, C, D, E, F, G, Q, R, P and T.Applicable for process connections codes 1, 2, 3, and 4.The unit of MWP (Max. working pressure) on the name plate of a housing is the same unit as specified by option codes D1, D3, and D4.The unit on the certificate is always Pa unit regardless of selection of option code D1, D3 or D4.Not applicable with process connections code for diaphragm seal system B, C, D, E, F, G, Q, R, P and T.Dry nitrogen gas is used for oil-prohibited use (option codes K1, K2, K5, K6, K41, K42, K45, and K46).Applicable for output signal codes D and J. The hardware error indicates faulty amplifier or capsule.