Model and Suffix Codes Model EJA110E Differential pressure transmitter Output signal -G Digital communication (PROFIBUS PA protocol, refer to GS 01C3T04-01EN) Measurement span (capsule) M 1 to 100 kPa (4 to 400 inH2O) Wetted parts material(1) A# Cover flange and process connector: Hastelloy C-276 equivalent(2)Capsule: Hastelloy C-276(3)Capsule gasket: PTFE TeflonVent/Drain plug: Hastelloy C-276(3) Process connections 5 without process connector (1/4 NPT female on the cover flanges) Bolts and nuts material G 316L SST Installation -7 Vertical piping, left side high pressure, and process connection downside Amplifier housing 1 Cast aluminum alloy Electrical connection 4 M20 female, two electrical connections without blind plugs Integral indicator E Digital indicator with the range setting switch (push button)(4) Mounting bracket N None Material certificate(5)(6) /M01 Cover flange(7) The ‘#’marks indicate the construction materials conform to NACE material recommendations per MR0175/ISO15156. Please refer to the latest standards for details. Selected materials also conform to NACE MR0103.Users must consider the characteristics of selected wetted parts material and the influence of process fluids. The use of inappropriate materials can result in the leakage of corrosive process fluids and cause injury to personnel and/or damage to plant facilities. It is also possible that the diaphragm itself can be damaged and that material from the broken diaphragm and the fill fluid can contaminate the user’s process fluids.Indicated material is equivalent to ASTM CW-12MW.Hastelloy C-276 or ASTM N10276.Not applicable for output signal code F.Material treceability certification, per EN 10204 3.1B.Not applicable with process connections code for diaphragm seal system B, C, D, E, F, G, Q, R, p and T.Applicable for process connections codes 0 and 5.