Характеристики

ConditionNew & Original in Factory Packing
Estimated Lead Time5 - 6 Months
Factory Warranty12 Months
ID каталога86569
ManufacturerYokogawa
ModelEJA110E Differential Pressure Transmitter
Part NumberEJA110E-FHS5G-92CDJ/KF22/D3/N4/HE
Shipping Weight8 Kg
АртикулEJA110E-FHS5G-92CDJ/KF22/D3/N4/HE
Срок поставки5 - 6 Months

Описание

EJA110E features include:0.055% Accuracy (0.04% Accuracy optional)0.1% Stability per 10 years90 ms Response TimeExida and TUV SIL 2 / SIL3 CertifiedMWP 2,300 psi (MWP 3,600 psi option)Local Parameter Setting (LPS)Ordering Information Model EJA110E Differential pressure transmitter Output signal -F Digital communication (FOUNDATION Fieldbus protocol, refer to GS 01C31T02-01EN) Measurement span (capsule) H 5 to 500 kPa (20 to 2000 inH2O) Wetted parts material(1) S# Cover flange and process connector: ASTM CF-8M(2)(3)Capsule: Hastelloy C-276(4) (Diaphragm), F316L SST, 316L SST (Others)Capsule gasket: Teflon-coated 316L SSTVent/Drain plug: 316 SST Process connections 5 without process connector (1/4 NPT female on the cover flanges) Bolts and nuts material G 316L SST Installation -9 Horizontal piping and left side high pressure Amplifier housing 2 ASTM CF-8M stainless steel(5) Electrical connection C 1/2 NPT female, two electrical connections and a SUS316 blind plug Integral indicator D Digital indicator(6) Mounting bracket J 316 SST 2-inch pipe mounting, flat type (for horizontal piping) ATEX /KF22 ATEX Flameproof Approval(7) Applicable Standard: EN 60079-0:2012/A11:2013, EN 60079-1:2007, EN 60079-31:2009 Certificate: KEMA 07ATEX0109 X II 2G, 2D Ex d IIC T6...T4 Gb, Ex tb IIIC T85°C Db Degree of protection: IP66/IP67 Amb. Temp. (Tamb) for gas-proof : T4; –50 to 75°C (–58 to 167°F), T5; –50 to 80°C (–58 to 176°F), T6; –50 to 75°C (–58 to 167°F) Process Temp. for gas-proof (Tp): –50 to T4; 120°C (248°F), T5; 100°C (212°F), T6; 85°C (185°F) Max. surface Temp. for dust-proof: T85°C (Tamb: –30 to 75°C, Tp: –30 to 85°C)(8) Calibration units(9) /D3 bar calibration (bar unit) Wired tag plate /N4 316 SST tag plate wired onto transmitter Fluoro-rubber O-ring /HE All O-rings of amplifier housing. Lower limit of ambient temperature: –15°C (5°F) The “*” marks indicate the most typical selection for each specification. Users must consider the characteristics of selected wetted parts material and the influence of process fluids. The use of inappropriate materials can result in the leakage of corrosive process fluids and cause injury to personnel and/or damage to plant facilities. It is also possible that the diaphragm itself can be damaged and that material from the broken diaphragm and the fill fluid can contaminate the user’s process fluids.Be very careful with highly corrosive process fluids such as hydrochloric acid, sulfuric acid, hydrogen sulfide, sodium hypochlorite, and high-temperature steam (150°C [302°F] or above). Contact Yokogawa for detailed information of the wetted parts material. Cast version of 316 SST. Equivalent to SCS14A.Intergranular corrosion test passed according to ASTM A262 Practice E.Not applicable for electrical connection code 0, 5, 7 and 9.Not applicable for output signal code G.Applicable for Electrical connection code 2, 4, 7, 9, C and D.Lower limit of ambient temperature is –15°C (5°F) when option code HE is specified.The unit of MWP (Max. working pressure) on the name plate of a housing is the same unit as specified by option codes D1, D3, and D4.