Характеристики

ConditionNew & Original in Factory Packing
Estimated Lead Time8 Weeks
Factory Warranty12 Months
ID каталога101552
ManufacturerRosemount
Model3144P Temperature Transmitter
Part Number3144PD1A1I1M5CNQ4QTG1HR7
Shipping Weight3 Kg
Артикул3144PD1A1I1M5CNQ4QTG1HR7

Описание

SpecificationsInput: Dual and single sensor capability with universal sensor inputs (RTD, T/C, mV, ohms)Output Signal: 4-20 mA /HART® protocol, FOUNDATION™ Fieldbus protocolHousing: Dual-compartment field mountDisplay/Interface: Large LCD display with percent range graph and buttons/switchesDiagnostics: Basic diagnostics, Hot Backup™ capability, sensor drift alert, thermocouple degradation, min/max trackingCalibration Options: Transmitter-sensor matching (Callendar-Van Dusen constants), custom trimCertifications/Approvals: SIL 2/3 certified to IEC 61508 by an independent 3rd party, hazardous location, marine type, see full specs for complete list of certificationsFeaturesIndustry-leading accuracy and reliability for best performance in critical control and safety applications.Transmitter-sensor matching improves measurement accuracy up to 75%.5-year long-term stability extends calibration intervals to reduce trips to the field.Rosemount X-well Technology measures temperature without a process penetration for reduced design, installation and maintenance costs. Ordering Information Model 3144P Temperature transmitter Housing style D1 Field mount housing, dual-compartment housing Material: AluminumConduit entry size: 1/2–14-in. NPT Transmitter output A 4—20 mA with digital signal based on HART Protocol Measurement configuration 1 Single-sensor input Product Certificates I1 ATEX intrinsic safety approval (includes standard IS and FISCO for Fieldbus units)¹ Display M5 LCD display Alarm level configuration CN NAMUR alarm and saturation levels, low alarm Calibration certification Q4 Calibration certificate (3-point calibration) Quality certification for safety QT Safety-certified to IEC 61508 with certificate of FMEDA data (HART only) External ground G1 External ground lug assembly HART revision configuration HR7 Configured for HART Revision 7 When IS approval is ordered on a FOUNDATION Fieldbus, both standard IS and FISCO IS approvals apply. The device label is marked appropriately.