Estimated Lead Time6 - 8 Weeks
ID каталога3145
Model3051C¹ - Coplanar Pressure TransmitterMeasurement type: D - DifferentialPressure range: 2 - ?250 to 250 inH2O (-621,60 to 621,60 mbar)Transmitter output: A² - 4-20 mA with Digital Signal Based on HART ProtocolMaterials of construction: 2 - [Process flange type] Coplanar; [Flange material] SST; [Drain/vent] SSTIsolating diaphragm: 2³ - 316L SSTO-ring: A - Glass-filled PTFESensor fill fluid: 1 - SiliconeHousing material: A - Aluminium; 1/2-14 NPT [Conduit entry size] Mounting bracket4: B4 - Coplan
Part Number3051CD2A22A1AB4I1M5Q4Q8Ordering Information
Shipping Weight5 Kg
Артикул3051CD2A22A1AB4I1M5Q4Q8

Описание

Part Number: 3051CD2A22A1AB4I1M5Q4Q8Ordering InformationModel: 3051C¹ - Coplanar Pressure TransmitterMeasurement type: D - DifferentialPressure range: 2 - ?250 to 250 inH2O (-621,60 to 621,60 mbar)Transmitter output: A² - 4-20 mA with Digital Signal Based on HART ProtocolMaterials of construction: 2 - [Process flange type] Coplanar; [Flange material] SST; [Drain/vent] SSTIsolating diaphragm: 2³ - 316L SSTO-ring: A - Glass-filled PTFESensor fill fluid: 1 - SiliconeHousing material: A - Aluminium; 1/2-14 NPT [Conduit entry size] Mounting bracket4: B4 - Coplanar flange bracket, all SST, 2-in. pipe and panelProduct certifications: I15 - ATEX Intrinsic Safety and DustDisplay and interface options: M5 - LCD DisplayCalibration certificate: Q4 - Calibration CertificateMaterial traceability certification: Q8 - Material Traceability Certification per EN 10204 3.1NOTE:Select Configuration Buttons (option code D4 or DZ) or Local Operator Interface (option code M4) if local configuration buttons are required.Option HR5 configures the HART output to HART Revision 5. Option HR7 configures the HART output to HART Revision 7. The device can be field configured to HART Revision 5 or 7 if desired. HART Revision 5 is the default HART output.Materials of Construction comply with recommendations per NACE MR0175/ISO 15156 for sour oil field production environments. Environmental limits apply to certain materials. Consult latest standard for details. Selected materials also conform to NACE MR0103 for sour refining environments.Panel mounting bolts are not supplied.Dust approval not applicable to Output Code X. See ?IEC 62591 (WirelessHART Protocol)? on page 62 for wireless approvals.

Документы