Ordering Information Model 266HSH Gauge Pressure Transmitter – BASE ACCURACY 0.06 % SENSOR - Span limit P 24 and 2400 kPa 0.24 and 24 bar 3.5 and 348 psi Diaphragm material / Fill fluid (wetted parts) S AISI 316 L ss Silicone oil (Note 1) NACE Process connection (wetted parts) B AISI 316 L ss 1/2 in. – 14 NPT female (Notes 1, 2) NACE Housing material and electrical connection A Aluminium alloy (barrel version) 1/2 in. – 14 NPT (Note 3) Output/Additional options 7 HART and 4 to 20 mA – Standard functionality (Note 1) Hazardous area certifications E7 Integral LCD LS Integrated digital LCD display (ONLY SELECTABLE WITH OUTPUT CODE 7) (Note 4) External non intrusive Z, S and WP pushbuttons R1 Transmitters with external pushbutton (ONLY SELECTABLE WITH OUTPUT CODE 7) Mounting bracket (shape and material) B6 For pipe/wall mounting – Carbon steel (Not suitable for AISI housing) Operating manual M5 English Notes.Not available with Sensor code ZNot available with diaphragm codes M, T, C, DNot available with Output code 9Not available with Hazardous area certification codes WM, WN, WP