RosemountOrdering InformationModel: 2088 - Pressure TransmitterMeasurement type: G - GagePressure ranges: 4 - -14.7 to 4,000 psi (-1,01 to 275,8 bar)Transmitter output¹: S - 4?20 mA dc/Digital HART ProtocolMaterials of construction²: 22Process connection: 316L SSTIsolating diaphragm: 316L SSTFill fluid: SiliconeProcess connection: A - 1/2?14 NPT femaleConduit entry: 2³ - M20 x 1.5Mounting brackets: B4 - SST mounting bracket with SST boltsProduct certifications: I1³ - ATEX Intrinsic SafetyDigital
Model
0306RT22BA11Model: 2088 Gage Pressure Transmitter
Part Number
2088G4S22A2B4I1C4S5Q4D4HR5Manifold
Shipping Weight
9 Kg
Артикул
2088G4S22A2B4I1C4S5Q4D4HR5
Модель
0306RT22BA11
Описание
Part Number: 2088G4S22A2B4I1C4S5Q4D4HR5Manifold Model: 0306RT22BA11Model: 2088 Gage Pressure TransmitterManufacturer: RosemountOrdering InformationModel: 2088 - Pressure TransmitterMeasurement type: G - GagePressure ranges: 4 - -14.7 to 4,000 psi (-1,01 to 275,8 bar)Transmitter output¹: S - 4?20 mA dc/Digital HART ProtocolMaterials of construction²: 22Process connection: 316L SSTIsolating diaphragm: 316L SSTFill fluid: SiliconeProcess connection: A - 1/2?14 NPT femaleConduit entry: 2³ - M20 x 1.5Mounting brackets: B4 - SST mounting bracket with SST boltsProduct certifications: I1³ - ATEX Intrinsic SafetyDigital signal: C4³ - NAMUR alarm and saturation levels, high alarmManifold assemblies4,5: S5 - Assemble to Rosemount 306 Integral ManifoldCalibration certificate: Q4 - Calibration certificateConfiguration buttons: D4 - Analog zero and spanHART Revision configuration6: HR57 - Configured for HART Revision 5HART Revision 5 is the default HART output. The Rosemount2088 with selectable HART can be factory or field configured to HART Revision 7. To order HART Revision 7 factory configured, add option code HR7.Materials of construction comply with recommendations per NACE MR0175/ISO 15156 for sour oil field production environments. Environmental limits apply to certain materials. Consult latest standard for details. Selected materials also conform to NACE MR0103 for sour refining environments.Not available with Low Power transmitter output code N.Use 1/2?14 NPT female process connection code A.?Assemble-to? items are specified separately and require a completed model number.Select configuration buttons (option code D4 or DZ) or local operator interface (option code M4) if local configuration buttons are required.Configures the HART output to HART Revision 5. The device can be field configured to HART Revision 7 if needed.